11 research outputs found

    Data storage and retrieval system

    Get PDF
    The Data Storage and Retrieval System (DSRS) consists of off-the-shelf system components integrated as a file server supporting very large files. These files are on the order of one gigabyte of data per file, although smaller files on the order of one megabyte can be accommodated as well. For instance, one gigabyte of data occupies approximately six 9 track tape reels (recorded at 6250 bpi). Due to this large volume of media, it was desirable to shrink the size of the proposed media to a single portable cassette. In addition to large size, a key requirement was that the data needs to be transferred to a (VME based) workstation at very high data rates. One gigabyte (GB) of data needed to be transferred from an archiveable media on a file server to a workstation in less than 5 minutes. Equivalent size, on-line data needed to be transferred in less than 3 minutes. These requirements imply effective transfer rates on the order of four to eight megabytes per second (4-8 MB/s). The DSRS also needed to be able to send and receive data from a variety of other sources accessible from an Ethernet local area network

    The Infrared Imaging Spectrograph (IRIS) for TMT: closed-loop adaptive optics while dithering

    Get PDF
    The InfraRed Imaging Spectrograph (IRIS) is the first-light client instrument for the Narrow Field Infrared Adaptive Optics System (NFIRAOS) on the Thirty Meter Telescope (TMT). IRIS includes three natural guide star (NGS) On-Instrument Wavefront Sensors (OIWFS) to measure tip/tilt and focus errors in the instrument focal plane. NFIRAOS also has an internal natural guide star wavefront sensor, and IRIS and NFIRAOS must precisely coordinate the motions of their wavefront sensor positioners to track the locations of NGSs while the telescope is dithering (offsetting the telescope to cover more area), to avoid a costly re-acquisition time penalty. First, we present an overview of the sequencing strategy for all of the involved subsystems. We then predict the motion of the telescope during dithers based on finite-element models provided by TMT, and finally analyze latency and jitter issues affecting the propagation of position demands from the telescope control system to individual motor controllers.Comment: 21 pages, 19 figures, SPIE (2018) 10707-4

    Over-expression of Eph and ephrin genes in advanced ovarian cancer: ephrin gene expression correlates with shortened survival

    Get PDF
    BACKGROUND: Increased expression of Eph receptor tyrosine kinases and their ephrin ligands has been implicated in tumor progression in a number of malignancies. This report describes aberrant expression of these genes in ovarian cancer, the commonest cause of death amongst gynaecological malignancies. METHODS: Eph and ephrin expression was determined using quantitative real time RT-PCR. Correlation of gene expression was measured using Spearman's rho statistic. Survival was analysed using log-rank analysis and (was visualised by) Kaplan-Meier survival curves. RESULTS: Greater than 10 fold over-expression of EphA1 and a more modest over-expression of EphA2 were observed in partially overlapping subsets of tumors. Over-expression of EphA1 strongly correlated (r = 0.801; p < 0.01) with the high affinity ligand ephrin A1. A similar trend was observed between EphA2 and ephrin A1 (r = 0.387; p = 0.06). A striking correlation of both ephrin A1 and ephrin A5 expression with poor survival (r = -0.470; p = 0.02 and r = -0.562; p < 0.01) was observed. Intriguingly, there was no correlation between survival and other clinical parameters or Eph expression. CONCLUSION: These data imply that increased levels of ephrins A1 and A5 in the presence of high expression of Ephs A1 and A2 lead to a more aggressive tumor phenotype. The known functions of Eph/ephrin signalling in cell de-adhesion and movement may explain the observed correlation of ephrin expression with poor prognosis
    corecore